PLFM-100 APPLICATION NOTES APPLICATION NOTE 310Z INSTALLING THE PLFM-100 IN THE COLLINS RADIO COMPANY 310Z-1 EXCITER The stereo option (786V-1) and/or the SCA option (786W-1) will directly interface the PLFM-100 input(s). 1) Remove Cards A3 (AFC discriminator), A5 (FM Modulator), and A6 (RF mixer). Keep A4 (AFC sync. detector) as this contains the driver circuits for the meter amp. 2) For composite input, connect composite source directly to green wire of PLFM-100. Both composite and pre-emphasis inputs can be used simultaneously. 3) Connect RF output of PLFM100 to J1 of Amplifier assembly A7. A convenient location for this insertion point would be the output cable from RF Mixer A6. There is a regulated +20 V source on connector XA6-pins 25 & 26, and ground on 27. This regulated voltage would then connect to the PLFM-100 12V regulator circuit schematic, for a +12v DC regulated source. 4) Add regulated 12v to PLFM-100 power input. There should be sufficient drive into Q1 of A7 full output. 9) Be sure to adequately shield PLFM-100 in a metal enclosure. The use of feed-thru bypass capacitors (100-1000pF) together with ferrite beads is highly recommended.